ARI -- WASP & HORNET SPRAY -- 6840-00N014860
===================== Product Identification =====================
Product ID:WASP & HORNET SPRAY
MSDS Date:01/01/1987
FSC:6840
NIIN:00N014860
=== Responsible Party ===
Company Name:ARI
Address:2523 S MCDONOUGH RD
City:ORCHARD HILL
State:GA
ZIP:30266
Country:US
Info Phone Num:800-241-5064
Emergency Phone Num:404-227-8222
CAGE:1L113
=== Contractor Identification ===
Company Name:ARI
Address:MCDONOUGH ROAD
Box:City:ORCHARD HILL
State:GA
ZIP:30266
Country:US
Phone:800-241-5064
CAGE:1L113
============= Composition/Information on Ingredients =============
Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 85%
OSHA PEL:350 PPM/450 STEL
ACGIH TLV:350 PPM/450STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1
Ingred Name:ODORLESS MINERAL SPIRITS
Fraction by Wt: 11.4%
ACGIH TLV:85 PPM (MFR)
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(ORAL, RAT)3000 MG/KG.
Health Hazards Acute and Chronic:EXCESSIVE PROLONGED INHALATION MAY
RESULT IN DROWSINESS, HEADACHES, NAUSEA, EYE AND LUNG IRRITATION.
CHLOROCARBON/CHLOROFLUOROCARBON (CFC) MATERIALS HAVE PRODUCED
SENSITIZATION OF THE MYOCARDIUM TO EP INEPHRINE IN LAB ANIMALS &
COULD HAVE ASIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (E.G.
EPINEPHRINE) (SEE EFTS OF OVEREXP
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:HLTH HAZ:MAY BE CONTRAINDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CHLOROCARBONS OR CFC'S .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE TO FRESH AIR. SKIN:FLUSH W/WATER. EYE:FLUSH
W/WATER FOR AT LEAST 15 MINUTES. INGEST:SEE MD IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:SOAK UP ON APPROPRIATE ABSORBENT MATERIAL.
DISCARD OR BURY IN PLACE WHICH WILL NOT REACH POTABLE OR
FISH-BEARING WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE WHERE TEMPERATURE EXCEEDS
120F.
Other Precautions:SEE LABEL. NO SMOKING IN AREA OF USE. DO NOT USE IN
THE GENERAL VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES.
HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR
PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . NONE REQUIRED AS LONG AS NOT USED IN
SMALL CLOSED AREA.
Ventilation:GENERAL VENTILATION IS ADEQUATE.
Protective Gloves:IF PRLNGD CNTCT, USE PROTECTIVE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:T6
Vapor Pres:90 PSIG
Spec Gravity:1.214
Solubility in Water:NEGLIGIBLE.
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:>90
================= Stability and Reactivity Data =================
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:DO NOT EXPOSE CAN TO HEAT OR TEMPERATURE
ABOVE 120F.
Hazardous Decomposition Products:ABNORMALLY HIGH TEMPERATURES:POSSIBLE
TRACE AMOUNTS OF PHOSGENE. HCL .
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT DISCHARGE INTO ANY BODY OF WATER. DISPOSE
OF I/A/W FEDERAL, STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their