ACE HARDWARE CORP -- FLOOR CLEANER -- 7930-00N058874
===================== Product Identification ===================== Product ID:FLOOR CLEANER MSDS Date:01/01/1991 FSC:7930 NIIN:00N058874 === Responsible Party === Company Name:ACE HARDWARE CORP Address:2200 KENSINGTON COURT City:OAK BROOK State:IL ZIP:60521 Country:US Info Phone Num:708-990-6600 Emergency Phone Num:800-843-6174 CAGE:ACEHA === Contractor Identification === Company Name:ACE HARDWARE CORPORATION Address:21901 SOUTH CENTRAL AVENUE City:MATTESON State:IL ZIP:60443 Country:US Phone:708-720-0600 CAGE:ACEHA ============= Composition/Information on Ingredients ============= Ingred Name:BENZYLETHYLDIMETHYLAMMONIUM CHLORIDE; (QUATERNARY AMMONIUM CHLORIDE) CAS:5197-80-8 OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:OCTYLPHENOXY POLYETHOXYETHANOL; (NONIONIC SURFACTANTS) CAS:9036-19-5 RTECS #:MD0907600 OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:WATER CAS:7732-18-5 RTECS #:ZC0110000 OSHA PEL:N/K ACGIH TLV:N/K ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE:EYES:MAY CAUSE IRRITATION. SKIN:PROLONGED EXPOSURE MAY CAUSE IRRITATION. INGEST:MAY CAUSE GASTROINTESTINAL IRRITATION, NAUSEA, DIARRHEA. Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:SEE HEALTH HAZARDS. Medical Cond Aggravated by Exposure:NONE KNOWN. ======================= First Aid Measures ======================= First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:FLUSH W/LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES HOLDING EYELIDS OPEN. SKIN:WASH W/MILD SOAP & WARM WATER. INGEST:D RINK 2 GLASSES OF WATER. DO NOT INDUCE VOMITING. CALL MD. ===================== Fire Fighting Measures ===================== Flash Point:NONE Extinguishing Media:USE MEDIA PROPER TO PRIMARY CAUSE OF FIRE. Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:NONE. ================== Accidental Release Measures ================== Spill Release Procedures:COLLECT & REUSE IF POSSIBLE, OR FLUSH TO SEWER, IF PERMITTED BY FEDERAL, STATE & LOCAL REGULATIONS. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:NORMAL GOOD HOUSEKEEPING TO PREVENT SPILLS. Other Precautions:KEEP OUT OF THE REACH OF CHILDREN. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN . NONE REQUIRED. Ventilation:MECHANICAL (GENERAL): SATISFACTORY. Protective Gloves:RUBBER OR PLASTIC GLOVES. Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS . Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA . OTHER PROT CLTHG/EQUIP AS NEEDED TO (SUPDAT) Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. Supplemental Safety and Health OTHER PROT EQUIP:PREVENT WETTING OF SKIN. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:212F,100C Vapor Pres:<30 Vapor Density:<1 Spec Gravity:1.025 (H*2O=1) pH:7 Evaporation Rate & Reference:<0.4 (BUTYL ACETATE=1) Solubility in Water:COMPLETE Appearance and Odor:CLEAR BLUE LIQUID; BLAND ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZING MATERIALS. Hazardous Decomposition Products:NONE. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF IN A MANNER APPROVED BY ALL FEDERAL, STATE & LOCAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.