ACE HARDWARE CORP -- FLOOR CLEANER -- 7930-00N058874
=====================  Product Identification  =====================

Product ID:FLOOR CLEANER
MSDS Date:01/01/1991
FSC:7930
NIIN:00N058874
=== Responsible Party ===
Company Name:ACE HARDWARE CORP
Address:2200 KENSINGTON COURT
City:OAK BROOK
State:IL
ZIP:60521
Country:US
Info Phone Num:708-990-6600
Emergency Phone Num:800-843-6174
CAGE:ACEHA
=== Contractor Identification ===
Company Name:ACE HARDWARE CORPORATION
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Phone:708-720-0600
CAGE:ACEHA

=============  Composition/Information on Ingredients  =============

Ingred Name:BENZYLETHYLDIMETHYLAMMONIUM CHLORIDE; (QUATERNARY AMMONIUM
    CHLORIDE)
CAS:5197-80-8
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:OCTYLPHENOXY POLYETHOXYETHANOL; (NONIONIC SURFACTANTS)
CAS:9036-19-5
RTECS #:MD0907600
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:MAY CAUSE IRRITATION.
    SKIN:PROLONGED EXPOSURE MAY CAUSE IRRITATION. INGEST:MAY CAUSE
    GASTROINTESTINAL IRRITATION, NAUSEA, DIARRHEA.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
    RESP) . EYES:FLUSH W/LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES
    HOLDING EYELIDS OPEN. SKIN:WASH W/MILD SOAP & WARM WATER. INGEST:D
    RINK 2 GLASSES OF WATER. DO NOT INDUCE VOMITING. CALL MD.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:USE MEDIA PROPER TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:COLLECT & REUSE IF POSSIBLE, OR FLUSH TO
    SEWER, IF PERMITTED BY FEDERAL, STATE & LOCAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NORMAL GOOD HOUSEKEEPING TO PREVENT
    SPILLS.
Other Precautions:KEEP OUT OF THE REACH OF CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN . NONE REQUIRED.
Ventilation:MECHANICAL (GENERAL): SATISFACTORY.
Protective Gloves:RUBBER OR PLASTIC GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . OTHER PROT CLTHG/EQUIP AS NEEDED TO (SUPDAT)
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
OTHER PROT EQUIP:PREVENT WETTING OF SKIN.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:<30
Vapor Density:<1
Spec Gravity:1.025 (H*2O=1)
pH:7
Evaporation Rate & Reference:<0.4 (BUTYL ACETATE=1)
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR BLUE LIQUID; BLAND ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING MATERIALS.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN A MANNER APPROVED BY ALL FEDERAL,
    STATE & LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.